Translators - Translator Resources
دليل خدمات الترجمة العالمي من بروز. كوم
 The translation workplace

فرنسي: Aiguilles Droites Surmoulées Tampographiées

أنجليزي translation: straight needles (with embossed overmoulded proximal end)






KudoZ
The KudoZ network provides a framework for translators... More

بند في مسرد المصطلحات مأخوذ من السؤال أدناه
فرنسي مصطلح أو جملة:Aiguilles Droites Surmoulées Tampographiées
أنجليزي ترجمة:straight needles (with embossed overmoulded proximal end)
تم إدخاله من قبل:Drmanu49
الخيارات:
- المساهمة في هذا البند

09:41 Jan 17, 2008Login or register (free) for more options.
ترجمة فرنسي إلى أنجليزي [للمحترفين]
Medical - الطب: علم الأدوية / Medical Devices
فرنسي مصطلح أو جملة: Aiguilles Droites Surmoulées Tampographiées
Heading on Batch Record document for urinary incontinence device.
mpt_21
المملكة المتحدة
ملاحظة(ات) إلى/من السائل
Janet Ratziu: 10:45 Jan 17, 2008: Hi Maureen. Could you give us some more context about the device itself?
mpt_21: 11:24 Jan 17, 2008: Aiguilles Droites Surmoulées Tampographiées - Thanks for your assistance, Janet. As it is a Batch Record document I have limited information. For "tampographiées" I only found "pad-printed" so I am non the wiser. It concerns a Kit used for urinary incontinence for which mesh is used
mpt_21: 16:31 Jan 17, 2008: "straight needles" - I did wonder about this myself but as the item underneath is "Aiguilles Gauches Surmoulées Tampographiées" I assume it must be "right".
Thanks very much for your help with this phrase.
Best wishes
Maureen
Drmanu49: 16:40 Jan 17, 2008: I am not sure about the needle's specific curvature. I would go with needle to be used on the right side with the needle passer. The embossing is there to indicate right or left?
Drmanu49: 16:40 Jan 17, 2008: I am not sure about the needle's specific curvature. I would go with needle to be used on the right side with the needle passer. The embossing is there to indicate right or left.
Drmanu49: 16:44 Jan 17, 2008: Yes, it is the passers which are specifically designed for left or right side use. See my ref ext.
liz askew: 17:39 Jan 17, 2008: Well, considering the very little context we were given, I am giving myself a bit pat on the back....!
Drmanu49: 17:44 Jan 17, 2008: I have no problem with patting Liz on the back! ;-)
liz askew: 17:49 Jan 17, 2008: I have to ask, how do we know from the context given that there are any passers?? Sure, you can assume this from researching the term, but is "passers" actually in the original French?? I think Maureen needs a big pat on the back too, for taking such a
liz askew: 17:50 Jan 17, 2008: task on board! Bye for now.
Drmanu49: 17:51 Jan 17, 2008: OK, pats for everybody.

straight needles (with embossed overmoulded proximal end)
شرح:
[0002] Urinary incontinence is a significant health concern worldwide. ... The needle portion has a substantially straight spacer portion along the handle ...
www.freshpatents.com/Transobturator-surgical-articles-and-m... - 34k -

Surgical correction of female urinary stress incontinence and kit .... substantially straight needle and the second type of needle comprises a needle with a ...
www.patentstorm.us/patents/7291104-claims.html - 65k

characterised in that the clip (18) has a hollow needle (42) which pierces ... around which the clip (18) is overmoulded by moulding of a plastic material. ...
www.freepatentsonline.com/EP0845395.html - 36k

--------------------------------------------------
Note added at 7 hrs (2008-01-17 16:42:27 GMT)
--------------------------------------------------

Specifically, the Monarc system simplifies rotation of the needle passer during insertion and extraction around the inferior aspect of the ischiopubic ramus. The 3-mm–diameter passers are specifically designed for right-side or left-side use. They are attached to fixed handles to create a natural wrist rotation. The sling connectors, meanwhile, facilitate rapid, effortless, and secure mesh placement and fixation.
استجابة مختارة من:

Drmanu49
فرنسا
ملاحظة من السائل إلى المجيب
Many thanks to you and Liz
3 نقطة كودوز تم منحها لهذه الإجابة



ملخص لجميع الترجمات الـأنجليزي المقدمة
3straight needles (with embossed overmoulded proximal end)
Drmanu49
3Right side shaped needlesliz askew


  

الإجابات

33 دقائق   درجة الثقة: Answerer confidence 3/5Answerer confidence 3/5
Right side shaped needles


شرح:
This is about as near as I can get...goodness knows what the "tampographiées" bit is about..

.http://216.239.59.104/search?q=cache:qFfnT1uydo4J:www.dinkyc...


tampographie = transfers


(WO/2005/105554) BEAM WITH AN OVER-MOULDED INSERT
- [ Translate this page ]
(WO/2005/105554) BEAM WITH AN OVER-MOULDED INSERT ... nervures de renfort (14), réalisées en matière plastique, surmoulées sur la traverse métallique (12). ...
www.wipo.org/pctdb/en/wo.jsp?wo=2005105554 - 14k - Cached - Similar pages

Transobturator surgical articles and methods invention
A surgical instrument for treating incontinence includes a handle ... needle is sized and shaped for use on either the patient's right side or left side. ...
www.freshpatents.com/Transobturator-surgical-articles-and-m... - 34k - Cached - Similar pages


[0021] In another aspect the `present invention comprises a surgical instrument for treating incontinence comprising a needle sized and shaped to either a) initially extend through an incision substantially adjacent a patient's obturator foramen and then through a vaginal incision, or b) initially extend through a vaginal incision and subsequently through an incision substantially adjacent a patient's obturator foramen. Notably, such a surgical instrument need not have substantial structure in three dimensions. Preferably, the needle comprises a pair of ends having surfaces for affording association with either an implantable sling material or a removable handle. In one embodiment, the needle is sized and shaped for use on either the patient's right side or left side.


Needles shaped for the right side

http://216.239.59.104/search?q=cache:pCycUUiAxH0J:www.jfponl...


The Monarc transobturator sling, introduced in Europe in January 2003, has been used successfully in more than 1,000 procedures.

Specifically, the Monarc system simplifies rotation of the needle passer during insertion and extraction around the inferior aspect of the ischiopubic ramus. The 3-mm–diameter passers are specifically designed for right-side or left-side use. They are attached to fixed handles to create a natural wrist rotation. The sling connectors, meanwhile, facilitate rapid, effortless, and secure mesh placement and fixation.

Insert your left index finger into the vaginal incision on the patient’s left side. Holding the right-side Monarc needle, introduce the needle tip perpendicularly through the skin incision.


--------------------------------------------------
Note added at 38 mins (2008-01-17 10:19:30 GMT)
--------------------------------------------------

I don't know whether it has anything to do with "pads"??

IngentaConnect An adjustable male sling for treating urinary ...
The pad is attached to the silicone cone columns that, after being passed with needles from the perineum to the abdominal wall, are adjusted with silicone ...
www.ingentaconnect.com/content/bsc/bju/2006/00000097/000000... - Similar pages

--------------------------------------------------
Note added at 44 mins (2008-01-17 10:25:58 GMT)
--------------------------------------------------

What can needles have to do with "pad printing"??

machine pour tampographie, pad print, printing plates
pad printing, siebdruck, tampographie, tampoimprenta, padprinting, tampoprinting · Company profile · What is pad printing? ...
www.tampograf.eu/ing/tampo.html - 11k - Cached - Similar pages

--------------------------------------------------
Note added at 53 mins (2008-01-17 10:34:08 GMT)
--------------------------------------------------

One last thought,

Could "tampographiées" = embossed??

i.e. with manufacturer's name or size of needle??

Who knows!

liz askew
المملكة المتحدة
اللغة الأصلية هي: أنجليزي
نقاط مستوى المحترفين في الفئة: 86

تعليقات الزملاء على هذه الإجابة والاستجابات من المجيب
محايد Drmanu49: You were going the right way Liz, I am not sure that the needle have a specific shape, that might be the passers.
7 ساعات
Login to enter a peer comment (or grade)


2 ساعات   درجة الثقة: Answerer confidence 3/5Answerer confidence 3/5
straight needles (with embossed overmoulded proximal end)


شرح:
[0002] Urinary incontinence is a significant health concern worldwide. ... The needle portion has a substantially straight spacer portion along the handle ...
www.freshpatents.com/Transobturator-surgical-articles-and-m... - 34k -

Surgical correction of female urinary stress incontinence and kit .... substantially straight needle and the second type of needle comprises a needle with a ...
www.patentstorm.us/patents/7291104-claims.html - 65k

characterised in that the clip (18) has a hollow needle (42) which pierces ... around which the clip (18) is overmoulded by moulding of a plastic material. ...
www.freepatentsonline.com/EP0845395.html - 36k

--------------------------------------------------
Note added at 7 hrs (2008-01-17 16:42:27 GMT)
--------------------------------------------------

Specifically, the Monarc system simplifies rotation of the needle passer during insertion and extraction around the inferior aspect of the ischiopubic ramus. The 3-mm–diameter passers are specifically designed for right-side or left-side use. They are attached to fixed handles to create a natural wrist rotation. The sling connectors, meanwhile, facilitate rapid, effortless, and secure mesh placement and fixation.

Drmanu49
فرنسا
متخصص في الحقل
اللغة الأصلية هي: أنجليزي, فرنسي
نقاط مستوى المحترفين في الفئة: 429
ملاحظة من السائل إلى المجيب
Many thanks to you and Liz
ملاحظات إلى المجيب
السائل:

السائل:


تعليقات الزملاء على هذه الإجابة والاستجابات من المجيب
محايد liz askew: Doh...I didn't even think about "straight"!! What was I doing?? But how do you know these have a proximal end??
17 دقائق
  -> from reading the refs Liz, the other end being the "piercing" tip.
Login to enter a peer comment (or grade)





العودة إلى قائمة كودوز